Unit description
3.3 Unit structure
Temperature Setting Knob
Control lamp
Button to reset
the temperature limiter
Exhaust air (G 1/8“)
(only for de-icing)
Connection for material outlet
(HP:
3
/
8
" NPSM / LP:
3
/
4
")
Heat exchanger
Connection for material inlet
(HP:
3
/
8
" NPSM / LP:
3
/
4
")
Main housing with all electrical
switches and heating elements
For use with air motor de-icing, these
holes must be pluged
Use the screws (M 10) included in the
assembly kit „Air Motor De-Icing“
Mounting screw* for the heat
exchanger (M 8)
Separating screw (M 12) for removing the heat ex-
changer from the housing (for air motor de-icing and
additional brass seal must be mounted)
Mounting screw* for the
heat exchanger (M 8)
Inbound air (G 1/4“)
(only for de-icing)
*) Tightening torque for fastening bolts: Tighten the first bolt to 20 Nm and the second one tight